lora driver: SX1276 reports incorrect RSSI
bug
Maintainer edit: Continuation from discussion at https://github.com/orgs/micropython/discussions/12989
For a Hope Radio RF96 (RFM96W) the RSSI readings seem to calculated incorrectly. I generally see about -110dBm where errors start creeping-in. Two other Micropython LoRa implementations report -120 or thereabout dBm for similar "errors*.
Is the formulae:
# units: dBm
rx_packet.rssi = self._reg_read(_REG_PKT_RSSI_VALUE) - (157 if self._pa_boost else 164)
valid for this chip? I do not understand why pa_boost is in this formulae.
CANDIDATE · ISSUE
micropython/lora, RSSI for Hope Radio devices
enhancement
All the RSSI implementations I have seen modify the returned RSSI value dependent on frequency (lf or hf). This distro appears to change it if the PA_BOOST is enabled?
# units: dBm
rx_packet.rssi = self._reg_read(_REG_PKT_RSSI_VAL) - (157 if self._pa_boost else 164)
Module used RF96 (RFM96W). If the above formulae is correct for other devices I could modify my sx127x.py
Hi @davefes,
Thanks for noticing this, it's a bug. It should be based on this section of the SX1276 datasheet:
Meaning the implementation should be something like:
Are you in a position to test this version and submit a PR to change it? If not, I'll get to it as soon as I have time.
Not until the weekend. Submit a PR ... it would be a first for me. As long as it works it's way into library I am OK with the "under-reporting".
I did check the RSSI at the receiver increased by turning off PA_BOOST at the receiver. Of course I didn't get an ACK at the sender. Another odd behaviour noted: the first RSSI after a re-boot is 5dB better then subsequent RSSI readings.
Thanks @davefes! Will leave this issue open until there's a fix.
Interesting. I assume that's probably an artifact of the module, although I don't know what it would be down to.
Change VALUE to VAL
rx_packet.rssi = self._reg_read(_REG_PKT_RSSI_VAL) - (157 if self._rf_freq_hz > 525_000_000 else 164)and RSSI values around -117dBm are when errors started appearing. Still see 4 or 5dB higher on the first RSSI reading. I am sure I haven't seen this happen on other implementations, but I will go back and check.
Edit:
just re-checked Wei's implementation and it reads -123 or -124dBm (at onset of errors) after a re-boot and that stays the same after that. The distance between RX and TX remained the same, so TX power and RX sensitivity appear to be identical with both S/Ws.
I believe you are both using the same RSSI register value. I did notice in the datasheet that there is another RSSI register:
Practically-speaking, I think the most useful aspect of RSSI is to give the user some rough idea of the excess link budget one has. If I see errors at -117dBm and my RSSI is -100dBm then I know I have ~17dB of margin.